Skip to content
+91 98434 32645 info@elcrystallab.com Monday – Saturday, 9:00 AM – 6:00 PM
NABL Accredited Laboratory Careers
EL CRYSTAL TESTING AND RESEARCH LABORATORY PRIVATE LIMITED
Aerial view of a wastewater treatment plant
Testing service

Wastewater Testing

ETP, STP and effluent monitoring to support pollution control board compliance.

EL Crystal tests treated and untreated wastewater from ETPs, STPs, CETPs and industrial outlets in Coimbatore, Tiruppur and across Tamil Nadu. Wastewater (effluent and sewage) chemical testing is in our NABL scope, including BOD, COD, TSS, TDS, oil and grease, chloride and sulphate. Our reports help industries, apartments and hospitals show compliance with TNPCB consent conditions.

EL Crystal Testing and Research Laboratory offers wastewater testing from our laboratory in Coimbatore, Tamil Nadu. ETP, STP and effluent monitoring to support pollution control board compliance. In addition, our team helps you choose the right wastewater testing parameters for your product and purpose.

Wastewater testing at EL Crystal laboratory

What our wastewater testing covers

Our wastewater testing covers pH, temperature, colour, bOD and COD, total suspended & dissolved solids, oil & grease, ammoniacal & total nitrogen, phosphate, chloride, sulphate, sulphide and heavy metals. Moreover, we can add other parameters when your buyer or regulator asks for them. As a result, you receive one clear report for every requirement.

Samples we test

We regularly test eTP inlet & outlet, sTP inlet & outlet, sewage, trade effluent, treated water for reuse and zLD / RO reject streams. Also, we can advise on similar products that are not listed here.

Who needs wastewater testing?

Our customers include textile dyeing & bleaching units, apartments, hotels & hospitals with STPs, food processing & dairy plants, engineering & electroplating units, tanneries and common effluent treatment plants. For example, many customers test every new batch, while others test when they change a supplier. Either way, a laboratory report gives you proof that you can share.

How to send samples for wastewater testing

First, 2 litres in a clean plastic can; 1 litre glass bottle for oil & grease. Next, label the sample with the product name, batch number and date. Then drop it at our Trichy Road laboratory or courier it to us. Finally, we email you a signed report.

Why choose EL Crystal for wastewater testing?

We combine qualified analysts, calibrated instruments and a documented quality system. Therefore, your results are accurate and easy to defend. Our methods follow the requirements of Bureau of Indian Standards and other recognised bodies. If you are in Coimbatore, see our wastewater testing lab in Coimbatore. When you are ready, contact our team for a quotation.

What we test

  • pH, temperature, colour
  • BOD and COD
  • Total suspended & dissolved solids
  • Oil & grease
  • Ammoniacal & total nitrogen, phosphate
  • Chloride, sulphate, sulphide
  • Heavy metals – chromium, lead, copper, zinc, nickel
  • Faecal coliforms for treated sewage

Relevant sample types

ETP inlet & outlet STP inlet & outlet Sewage Trade effluent Treated water for reuse ZLD / RO reject streams

Industries we serve

  • Textile dyeing & bleaching units
  • Apartments, hotels & hospitals with STPs
  • Food processing & dairy plants
  • Engineering & electroplating units
  • Tanneries
  • Common effluent treatment plants

Customer requirements

  • 2 litres in a clean plastic can; 1 litre glass bottle for oil & grease
  • BOD samples must be chilled and reach the lab within 24 hours
  • Label sampling point, date and time

Methods & standards referenced: IS 3025 series · APHA Standard Methods

Selected parameters are within our NABL accreditation scope

Chemical parameters for wastewater (effluent/sewage), including pH, BOD (3 days at 27 °C), COD, TSS, TDS, oil and grease, chloride, sulphate, sulphide, ammoniacal nitrogen and phosphate, are within our NABL scope (ISO/IEC 17025:2017, Chemical discipline). Heavy metals and faecal coliforms are offered outside our NABL scope.

View our accreditation certificate and scope

Wastewater Testing — FAQs

How often should ETP or STP water be tested?

The frequency is set in your consent order. Many units test monthly or quarterly; we can set up a routine schedule with pickup.

Why does BOD testing take several days?

The standard BOD test measures oxygen consumed over an incubation period, so the result is available only after incubation is complete.

What is the difference between BOD and COD?

BOD (biochemical oxygen demand) measures the oxygen bacteria use to break down organic matter over 3 days at 27 °C. COD (chemical oxygen demand) measures the oxygen needed to oxidise organic and inorganic matter chemically, in about 2 hours. COD is always higher than BOD for the same sample.

Do you collect effluent samples from Tiruppur?

Yes. We serve textile, dyeing and processing units in Tiruppur, Erode, Karur and Coimbatore through pickup, courier or drop-off.

Are your effluent reports NABL accredited?

Yes, for chemical parameters. Wastewater (effluent/sewage) parameters such as BOD, COD, TSS, TDS, oil and grease, chloride and sulphate are in our NABL scope (ISO/IEC 17025:2017). Heavy metals and coliforms are outside our NABL scope. Check your consent order for any lab-recognition requirement.

How should I collect an effluent sample?

Collect a composite sample over the shift if your consent order requires it, otherwise a grab sample at the final outlet. Use a clean 2-litre plastic can, a separate glass bottle for oil and grease, keep it cool and deliver within 24 hours.

How testing works

From sample to signed report — step by step

A clear, documented process so you always know where your sample is and what happens next.

  1. Enquiry & quotation

    Share your product, the parameters or the standard you must comply with. We confirm the test plan, price, sample quantity and timeline.

  2. Sample submission

    Deliver to our laboratory, send by courier or request a pickup. Each sample is inspected, coded and logged with a chain of custody.

  3. Analysis & quality checks

    Qualified analysts test using validated methods and calibrated instruments, with quality-control checks run alongside your sample.

  4. Reviewed test report

    Results are technically reviewed and issued as a signed report by email, with our team available to explain the findings.

Packing your sample

  • Use a clean, sealed, food-grade or sterile container
  • Keep packaged products in their original, unopened pack
  • Label with product name, batch number and date

Transport

  • Water for microbiology: chilled and delivered within 24 hours
  • Perishable foods: chilled, in an insulated box with ice packs
  • Courier from anywhere in Tamil Nadu — ask us for the address label

Include with the sample

  • Completed test request form or our quotation reference
  • The parameters or standard you need to meet
  • Billing name, GST number and report contact
Customer enquiry

Request a quote for Wastewater Testing

Tell us what you need tested. Our technical team will recommend the right parameters and send a clear quotation — usually the same working day.

Test list, specification or product label — PDF, image, Word or Excel. Allowed: PDF, JPG, JPEG, PNG, DOC, DOCX, XLS, XLSX · max 5 MB

Your details are confidential and used only to respond to you.